Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
1.
Dentomaxillofac Radiol ; 52(8): 20230109, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37665027

RESUMO

OBJECTIVES: To assess the effect of standard filtered back projection (FBP) and iterative reconstruction (IR) methods on CBCT image noise and processing time (PT), acquired with various acquisition parameters with and without metal artefact reduction (MAR). METHODS: CBCT scans using the Midmark EIOS unit of a human mandible embedded in soft tissue equivalent material with and without the presence of an implant at mandibular first molar region were acquired at various acquisition settings (milliamperages [4mA-14mA], FOV [5 × 5, 6 × 8, 9 × 10 cm], and resolutions [low, standard, high] and reconstructed using standard FBP and IR, and with and without MAR. The processing time was recorded for each reconstruction. ImageJ was used to analyze specific axial images. Radial transaxial fiducial lines were created relative to the implant site. Standard deviations of the gray density values (image noise) were calculated at fixed distances on the fiducial lines on the buccal and lingual aspects at specific axial levels, and mean values for FBP and IR were compared using paired t-tests. Significance was defined as p < 0.05. RESULTS: The overall mean for image noise (± SD) for FBP was 198.65 ± 55.58 and 99.84 ± 16.28 for IR. IR significantly decreased image noise compared to FBP at all acquisition parameters (p < 0.05). Noise reduction among different scanning protocols ranged between 29.7% (5 × 5 cm FOV) and 58.1% (5mA). IR increased processing time by an average of 35.1 s. CONCLUSIONS: IR significantly reduces CBCT image noise compared to standard FBP without substantially increasing processing time.


Assuntos
Tomografia Computadorizada de Feixe Cônico Espiral , Humanos , Doses de Radiação , Imagens de Fantasmas , Tomografia Computadorizada por Raios X/métodos , Cabeça , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Algoritmos , Processamento de Imagem Assistida por Computador/métodos
2.
Med Phys ; 50(11): 6714-6736, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37602774

RESUMO

BACKGROUND: Optimization of dental cone beam computed tomography (CBCT) imaging is still in a preliminary stage and should be addressed using task-based methods. Dedicated models containing relevant clinical tasks for image quality studies have yet to be developed. PURPOSE: To present a methodology to develop and validate a virtual adult anthropomorphic voxel phantom for use in task-based image quality optimization studies in dental CBCT imaging research, focusing on root fracture (RF) detection tasks in the presence of metal artefacts. METHODS: The phantom was developed from a CBCT scan with an isotropic voxel size of 0.2 mm, from which the main dental structures, mandible and maxilla were segmented. The missing large anatomical structures, including the spine, skull and remaining soft tissues, were segmented from a lower resolution full skull scan. Anatomical abnormalities were absent in the areas of interest. Fine detailed dental structures, that could not be segmented due to the limited resolution and noise in the clinical data, were modelled using a-priori anatomical knowledge. Model resolution of the teeth was therefore increased to 0.05 mm. Models of RFs as well as dental restorations to create the artefacts, were developed, and could be inserted in the phantom in any desired configuration. Simulated CBCT images of the models were generated using a newly developed multi-resolution simulation framework that incorporated the geometry, beam quality, noise and spatial resolution characteristics of a real dental CBCT scanner. Ray-tracing and Monte Carlo techniques were used to create the projection images, which were reconstructed using the classical FDK algorithm. Validation of the models was assessed by measurements of different tooth lengths, the pulp volume and the mandible, and comparison with reference values. Additionally, the simulated images were used in a reader study in which two oral radiologists had to score the realism level of the model's normal anatomy, as well as the modelled RFs and restorations. RESULTS: A model of an adult head, as well as models of RFs and different types of dental restorations were created. Anatomical measurements were consistent with ranges reported in literature. For the tooth length measurements, the deviations from the mean reference values were less than 20%. In 77% of all the measurements, the deviations were within 10.1%. The pulp volumes, and mandible measurements were within one standard deviation of the reference values. Regarding the normal anatomy, both readers considered the realism level of the dental structures to be good. Background structures received a lower realism score due to the lack of detailed enough trabecular bone structure, which was expected but not the focus of this study. All modelled RFs were scored at least adequate by at least one of the readers, both in appearance and position. The realism level of the modelled restorations was considered to be good. CONCLUSIONS: A methodology was proposed to develop and validate an anthropomorphic voxel phantom for image quality optimization studies in dental CBCT imaging, with a main focus on RF detection tasks. The methodology can be extended further to create more models representative of the clinical population.


Assuntos
Tomografia Computadorizada de Feixe Cônico Espiral , Imagens de Fantasmas , Tomografia Computadorizada de Feixe Cônico/métodos , Cabeça , Crânio
3.
Restor Dent Endod ; 48(2): e16, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37284345

RESUMO

Objectives: The aim of this study was to evaluate the influence of peak kilovoltage (kVp) and a metal artifact reduction (MAR) tool on image quality and the diagnosis of vertical root fracture (VRF) in cone-beam computed tomography (CBCT). Materials and Methods: Twenty single-rooted human teeth filled with an intracanal metal post were divided into 2 groups: control (n = 10) and VRF (n = 10). Each tooth was placed into the socket of a dry mandible, and CBCT scans were acquired using a Picasso Trio varying the kVp (70, 80, 90, or 99), and the use of MAR (with or without). The examinations were assessed by 5 examiners for the diagnosis of VRF using a 5-point scale. A subjective evaluation of the expression of artifacts was done by comparing random axial images of the studied protocols. The results of the diagnoses were analyzed using 2-way analysis of variance and the Tukey post hoc test, the subjective evaluations were compared using the Friedman test, and intra-examiner reproducibility was evaluated using the weighted kappa test (α = 5%). Results: The kVp and MAR did not influence the diagnosis of VRF (p > 0.05). According to the subjective classification, the 99 kVp protocol with MAR demonstrated the least expression of artifacts, while the 70 kVp protocol without MAR led to the most artifacts. Conclusions: Protocols with higher kVp combined with MAR improved the image quality of CBCT examinations. However, those factors did not lead to an improvement in the diagnosis of VRF.

4.
Odovtos (En línea) ; 24(1)abr. 2022.
Artigo em Inglês | LILACS, SaludCR | ID: biblio-1386570

RESUMO

Abstract The objective of this study was to evaluate perception and feelings experienced by dentistry professors and students about distance learning during the COVID-19 pandemic. Fifty professors and fifty- two students reported the perceptions and implications of distance learning imposed by the pandemic of COVID-19. The participants' answers were analyzed using the qualitative-quantitative method of the collective subject's discourse. The answers were summarized in central ideas, distributed in absolute and relative frequency. The answers with similar central ideas were grouped, obtaining the discourse of the collective subject. The similar central ideas about distance learning addressed by professors and students were: suitable for didactic courses; limited laboratory and clinical courses, and internet access difficulties. Specifically for professors: a complement to classroom teaching; stress and learning with digital technologies; difficulty in reconciling classes with domestic activities; concerns with motivation and interaction with students; asynchronous lectures favor knowledge fixation, and synchronous lectures favor interaction with students; unreliable assessment methods; concern about returning to face-to-face classes. For the students: it was applied to all courses; demotivating; fundamental to guide studies; professors' commitment; long lectures; excessive school activities; difficult attendance control and evaluation; the comfort of being at home; impact on research. Professors considered distance learning as a learning opportunity on how to use digital technologies but too limited for lab and clinical activities and interaction with students. Students found it discouraging due to the absence of practical classes and excessive school activities.


Resumen: Evaluar la percepción y los sentimientos manifestados por profesores y estudiantes de odontología sobre la educación a distancia durante la pandemia por COVID-19. 50 profesores y 52 estudiantes informaron las percepciones e implicaciones del aprendizaje a distancia impuestas por motivo de la pandemia de COVID-19. Respuestas de los participantes fueron analizadas utilizando el método cualitativo-cuantitativo del discurso del sujeto colectivo. Respuestas se agruparon en ideas centrales, obteniendo el discurso del sujeto colectivo y fueron distribuidas en frecuencia absoluta y relativa. Ideas centrales similares entre profesores y estudiantes sobre el aprendizaje a distancia fueron: a) es adecuado para cursos didácticos; b) limitado para cursos de laboratorio y clínicos; c) presenta dificultades devido al acceso a Internet. Específicamente para profesores: a) complemento a la docencia en el aula; b) aumenta el estrés devido a la curva de aprendizaje con tecnologías digitales; c) dificultad para conciliar las clases con las actividades domésticas; d) preocupaciones con la motivación y la interacción con los estudiantes; e) las clases asincrónicas favorecen la fijación del conocimiento y las clases sincrónicas favorecen la interacción con los estudiantes; f) métodos de evaluación poco fiables; y g) preocupación por volver a las clases presenciales. Para los estudiantes: a) se aplicó a todos los cursos; b) desmotivador fundamental para orientar los estudios; c) compromiso de los profesores; d) conferencias largas; e) actividades escolares excesivas; f) difícil control y evaluación de asistencia; g) la comodidad de estar en casa; y h) impacto en la investigación. Profesores consideraron el aprendizaje a distancia como una oportunidad de aprendizaje sobre cómo utilizar las tecnologías digitales, pero demasiado limitado para las actividades de laboratorio y clínicas y la interacción con los estudiantes. Estudiantes lo encontraron desalentador debido a la ausencia de clases prácticas y al exceso de actividades escolares.


Assuntos
Humanos , Educação a Distância , Educação em Odontologia , COVID-19
5.
Eur J Dent ; 16(2): 381-385, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34902874

RESUMO

OBJECTIVE: This study was developed to evaluate the influence of voxel size on bone measurements for implant planning. MATERIALS AND METHODS: The research was performed by using edentulous synthetic human mandibles with different levels of bone resorption. For each mandible, height and bone thickness were measured with a digital caliper. The PaX-i3d device was used to acquire the volumes of the five mandibles, with 50kVp, 4 mA, and a voxel size of 0.08 mm. After the acquisition, the images were reconstructed in the software CS three-dimensional Imaging, with four different sizes of voxels: 0.1, 0.2, 0.3, and 0.4 mm. All volumes were analyzed by a single evaluator who performed measurements to obtain bone height and thickness, using the reference points that were considered in obtaining the gold standard. The data were analyzed by ANOVA with a significance level of 5%. RESULTS: There was no significant difference in the measurements obtained with different voxel sizes, both for bone height measurements and bone thickness. There was no statistically significant difference in measurements in thickness in comparison to the gold standard. CONCLUSION: When necessary, to measure height and bone thickness, it is possible to recommend voxel images of larger size (0.40 mm) without compromising the quality of the patient's clinical planning.

6.
Odovtos (En línea) ; 23(3)dic. 2021.
Artigo em Inglês | LILACS, SaludCR | ID: biblio-1386562

RESUMO

ABSTRACT: The objective of this study was to assess the use and experience with digital communication tools among dentistry professors and students to adapt to distance learning during the Covid-19 pandemic. Nine hundread and ninety five participants (479 dentistry professors and 516 students) from countries in North America, Latin America, Brazil, Europe, Asia, Oceania, and the Middle East answered a questionnaire about motivation/stress/anxiety; practice with digital technologies; synchronous/asynchronous communication technologies (difficulties/benefits), and which ones would they prefer using when returning to college. Data were analyzed by the Chi-square test and Fisher's exact (α=0.05). Motivation was more affected among the female professors, male students, and Brazilians (p<0.05). Concern about the academic future, was higher among female students, up to 30 years old, from Latin America and Brazil, and lower for European professors (p<0.05). Anxiety and stress were higher for undergraduate students up to 20 years old from Latin America and Brazil (p<0.05). European professors used more synchronous videoconferencing services for lectures/questions, while Brazilians used more text messaging applications for answering questions (p<0.05). Latin American professors used more surveys for evaluation (p<0.05). Brazilian professors indicated that they would use "online meetings" and "survey administration services" when returning to face-to-face activities and European professors/students would use "email" (p<0.05). Professors from Asia/Oceania/Middle East and professors/students from Brazil indicated "remote activities were important for students not to be inactive" (p<0.05). Efforts were made to adapt Dentistry's teaching to distance learning during the COVID-19 pandemic. However, the technologies used for this, feelings, and experiences differed between professors and students.


RESUMEN: El objetivo de este estudio fue evaluar el uso y la experiencia con herramientas de comunicación digital entre profesores y estudiantes de odontología para adaptarse al aprendizaje a distancia durante la pandemia Covid-19. Novecientos noventa y cinco participantes (479 profesores y 516 estudiantes de odontología) de países de diferentes regiones de América del Norte, América Latina, Brasil, Europa, Asia, Oceanía y Oriente Medio respondieron un cuestionario sobre motivación/ estrés/ansiedad; práctica con tecnologías digitales; tecnologías de comunicación sincrónicas/asincrónicas (dificultades/beneficios), y cuáles continuarían usando al regresar a la universidad. Los datos se analizaron mediante las pruebas Chi-cuadrado y exacta de Fisher (α=0,05). La motivación se vio más afectada entre las profesoras, estudiantes y brasileños (p<0,05). La preocupación por el futuro académico fue mayor entre las estudiantes, hasta los 30 años, de América Latina y Brasil, y menor para el profesorado europeo (p<0,05). El estrés fue mayor para el estudiantado de pregrado de Latinoamérica y Brasil hasta los 20 años (p<0.05). El profesorado europeo utilizó más servicios de videoconferencia sincrónica para clases y consultas, mientras que el brasileño utilizó más aplicaciones de mensajería de texto para consultas (p<0,05). El profesorado latinoamericano utilizó más encuestas para evaluación (p<0.05). El profesorado brasileño indicó que utilizaría "reuniones en línea" y "servicios de encuestas" cuando regresaran a la presencialidad, mientras que el profesorado/ estudiantado europeo utilizaría "correo electrónico" (p<0,05). El profesorado de Asia/ Oceanía/Medio Oriente y profesorado/estudiantado de Brasil indicó que "las actividades remotas eran importantes para que el estudiantado no estuviera inactivo" (p<0,05). Se relizaron esfuerzos para adaptar la enseñanza de la Odontología al aprendizaje a distancia durante la pandemia de COVID-19. Sin embargo, las tecnologías utilizadas y las experiencias difirieron entre profesores y estudiantes.


Assuntos
Educação a Distância , Educação em Odontologia , COVID-19 , Realidade Virtual
7.
Dentomaxillofac Radiol ; 50(3): 20200191, 2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-32941781

RESUMO

OBJECTIVES: To present the ballistic gelatin as a new material capable of simulating the soft tissues in cone-beam CT (CBCT) images. METHODS: CBCT images of three piglet heads were acquired with their soft tissues intact (standard group). Subsequently, the piglet heads were fixed in a container using metallic pins and moulded with acrylic resin; the soft tissues were then removed and replaced by ballistic gelatin, with the same thickness of the original soft tissues. The images were evaluated by two oral radiologists, to check the adaptation on bone surfaces, thickness and density, penetration into large bone cavities and cancellous bone, and the presence of air bubbles using a 5-score scale. Additionally, an objective analysis was carried out by one oral radiologist. For each CBCT scan, three axial reconstructions were selected to represent the mandibular, occlusal, and maxillary levels. The mean and standard deviation (SD) of the grey values were calculated in four regions of interest determined on soft tissue areas and compared by two-way ANOVA. RESULTS: The ballistic gelatin showed subjective scores ranging from good to excellent for all parameters evaluated. There was no significant difference in the mean and SD values of the grey values between ballistic gelatin and the gold standard groups for all levels (p > 0.05). Higher SD values were observed in the occlusal level for both groups (p < 0.05). CONCLUSIONS: Ballistic gelatin has visual and objective similarity with the gold standard. Thus, the ballistic gelatin is a promising material capable of simulating soft tissues in CBCT images.


Assuntos
Gelatina , Tomografia Computadorizada de Feixe Cônico Espiral , Animais , Tomografia Computadorizada de Feixe Cônico , Humanos , Mandíbula/diagnóstico por imagem , Radiografia Dentária , Suínos
8.
Dentomaxillofac Radiol ; 49(6): 20190500, 2020 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-32302219

RESUMO

OBJECTIVES: To assess, objectively to determine the deterioration of the photostimulable phosphor plates (PSPs) after several acquisitions. METHODS: Two new PSPs without preliminary use were exposed with an intraoral X-ray unit, and the EXPRESS® (Instrumentarium Imaging, Tuusula, Finland) unit was used for scanning of the PSPs. A 12-stepwedge aluminum scale were used superimposed with the PSPs during the X-rays exposures to perform the objective analyses. Objective analysis was carried out by mean gray values using the Image J software through a region of interest (ROI) of 0.1 × 0.1 mm, and the data were analyzed statistically using ANOVA. RESULTS: For each, the Express® PSP a total of 1800 images were acquired during 60 days. The objective analysis showed loss of the mean gray values between the initial and final images. Besides, the percentage of mean gray values' loss was between 0.7%, for the thickest step, and 8.4%, for the lowest thickness step. CONCLUSION: After many X-ray exposures of the Express® PSP a singular deterioration in the mean gray values could be observed.


Assuntos
Radiografia Dentária Digital , Ecrans Intensificadores para Raios X
9.
Imaging Sci Dent ; 50(4): 339-346, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33409143

RESUMO

PURPOSE: The purpose of this study was to evaluate the image quality, diagnostic efficacy, and radiation dose associated with the use of a cadmium telluride (CdTe) detector, compared to charge-coupled device (CCD) and complementary metal oxide semiconductor (CMOS) detectors. MATERIALS AND METHODS: Lateral cephalographs of a phantom (type 1) composed of synthetic polymer filled with water and another phantom (type 2) composed of human skull macerated with polymer coating were obtained with CdTe, CCD, and CMOS detectors. Dosimeters placed on the type 2 phantom were used to measure radiation. Noise levels from each image were also measured. McNamara cephalometric analysis was conducted, the dentoskeletal configurations were assessed, and a subjective evaluation of image quality was conducted. Parametric data were compared via 1-way analysis of variance with the Tukey post-hoc test, with a significance level of 5%. Subjective image quality and dentoskeletal configuration were described qualitatively. RESULTS: A statistically significant difference was found among the images obtained with the 3 detectors (P<0.05), with the lowest noise level observed among the images obtained with the CdTe detector and a higher subjective preference demonstrated for those images. For the cephalometric analyses, no significant difference (P>0.05) was observed, and perfect agreement was seen with regard to the classifications obtained from the images acquired using the 3 detectors. The radiation dose associated with the CMOS detector was higher than the doses associated with the CCD (P<0.05) and CdTe detectors (P<0.05). CONCLUSION: Considering the evaluated parameters, the CdTe detector is recommended for use in clinical practice.

10.
Dentomaxillofac Radiol ; 49(1): 20190240, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31530012

RESUMO

OBJECTIVES: To evaluate the impact of movement and motion-artefact correction systems on CBCT image quality and interpretability of simulated diagnostic tasks for aligned and lateral-offset detectors. METHODS: A human skull simulating three diagnostic tasks (implant planning in the anterior maxilla, implant planning in the left-side-mandible and mandibular molar furcation assessment in the right-side-mandible) was mounted on a robot performing six movement types. Four CBCT units were used: Cranex 3Dx (CRA), Ortophos SL (ORT), Promax 3D Mid (PRO), and X1. Protocols were tested with aligned (CRA, ORT, PRO, and X1) and lateral-offset (CRA and PRO) detectors and two motion-artefact correction systems (PRO and X1). Movements were performed at one moment-in-time (t1), for units with an aligned detector, and three moments-in-time (t1-first-half of the acquisition, t2-second-half, t3-both) for the units with a lateral-offset detector. 98 volumes were acquired. Images were scored by three observers, blinded to the unit and presence of movement, for motion-related stripe artefacts, overall unsharpness, and interpretability. Fleiss' κ was used to assess interobserver agreement. RESULTS: Interobserver agreement was substantial for all parameters (0.66-0.68). For aligned detectors, in all diagnostic tasks a motion-artefact correction system influenced image interpretability. For lateral-offset detectors, the interpretability varied according to the unit and moment-in-time, in which the movement was performed. PRO motion-artefact correction system was less effective for the offset detector than its aligned counterpart. CONCLUSION: Motion-artefact correction systems enhanced image quality and interpretability for units with aligned detectors but were less effective for those with lateral-offset detectors.


Assuntos
Movimento , Tomografia Computadorizada de Feixe Cônico Espiral , Artefatos , Humanos , Crânio/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico Espiral/normas
11.
Dentomaxillofac Radiol ; 49(2): 20190077, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31469317

RESUMO

OBJECTIVES: To assess the effect of CBCT detector position (aligned/lateral-offset) on image technical parameters (mean voxel value - MVV, standard deviation of voxel value (SDVV) distribution), comparing peripheral regions of interest (ROIs) to the central ROI in CBCT volumes. METHODS: 40 CBCT volumes of a wax phantom were acquired in six units with aligned and/or lateral-offset detectors: Cranex 3Dx (CRA), Ortophos SL (ORT), Picasso Trio (PIC), Promax 3D Mid (PRO), Scanora 3D (SCA), and X1. Four image-acquisition protocols used an aligned detector, and four a lateral-offset detector. In each volume, 13 ROIs (12 peripheral and 1 central) were evaluated. MVV and SDVV of the peripheral ROI were compared to those of the central ROI in the volume. MVVD (the difference in percentage, between the MVV of a peripheral and the central ROI) was calculated. RESULTS: For aligned-detectors, MVV increased (ORT and PRO) or decreased (CRA and X1) in the ROIs farther from the centre. For lateral-offset detectors, ROIs farther from the centre showed increased MVV. SDVV for most aligned detectors was lower, the nearer the ROI was to the centre. For lateral-offset detectors, it was lower for the peripheral ROIs, except with PIC. Range for MVVD was -32.8% to 22.8% for units with aligned detectors, and -20.7% to 69.5% for lateral-offset detectors. CONCLUSION: Lateral-offset detectors to acquire CBCT images significantly change SDVV distribution within the field-of-view, and lead to MVVD with increased range, compared to aligned detectors. This must be taken in consideration in the clinic, if voxel-value dependent measurements are to be performed.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Radiografia Dentária Digital , Tomografia Computadorizada de Feixe Cônico Espiral , Humanos , Imagens de Fantasmas
13.
Dentomaxillofac Radiol ; 48(8): 20190058, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31276425

RESUMO

OBJECTIVES: To quantify the artefacts production and the performance of the metal artefact reduction (MAR) tool, enabled before or after the acquisition, in cortical plates (buccal and lingual) and other regions adjacent to zirconium implants. METHODS: Cone beam CT scans were acquired using the OP300 Maxio unit before (control group) and after (implant group) the insertion of a zirconium implant into the posterior region of a dry mandible. Three conditions of MAR tool were tested: "without MAR", with "MAR activated after acquisition", and with "MAR activated before acquisition". The standard deviation (SD), contrast-to-noise ratio (CNR) and voxel values were calculated in the buccal and lingual cortical plates, medullary bone and water region, close to the implant. The structural bone analysis was performed in the medullary bone close to the implant. RESULTS: Overall, in control and implant groups, the lingual cortical had higher SD, lower CNR and lower voxel values than the buccal cortical, regardless of the MAR condition (p < 0.05). Implant caused higher SD values and lower voxel values in adjacent regions "without MAR" (p < 0.05). MAR activation decreased SD and changed voxel values when the implant was present, regardless of MAR activation mode (p < 0.05). The activation of MAR increased the trabecular thickness values for the implant group (p < 0.05). CONCLUSION: The expression of artefacts adjacent to zirconium implants is greater in the lingual than in the buccal cortical. The greater the expression of artefacts in this region, the greater the effectiveness of the MAR tool in homogenizing the grey values, regardless of the time of its activation.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Implantes Dentários , Artefatos , Humanos , Mandíbula/diagnóstico por imagem , Zircônio
14.
Imaging Sci Dent ; 49(2): 97-102, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31281786

RESUMO

PURPOSE: This study was conducted to evaluate the effect of different spatial resolutions of a photostimulable phosphor plate (PSP) radiography system on the detection of proximal caries lesions. MATERIALS AND METHODS: Forty-five extracted human permanent teeth were radiographed using a PSP system (VistaScan Perio Plus) and scanned at the 4 resolutions (10 lp/mm, 20 lp/mm, 25 lp/mm, and 40 lp/mm) available in the system. Three independent examiners scored the images for the presence and absence of proximal caries lesions using a 5-point scale. The presence or absence of caries was confirmed by histological sections of the examined teeth (defined as the gold standard). Intra- and inter-observer reproducibility was calculated by the weighted kappa test. One-way analysis of variance with the post hoc Tukey test was used to compare the area under the receiver operating characteristic curve for the classifications made with each resolution. RESULTS: For the detection of enamel lesions, the spatial resolution of 10 lp/mm was significantly superior to the other resolutions. However, the spatial resolution did not affect the detection of caries lesions in dentin (P>0.05). CONCLUSION: Spatial resolution may influence the accuracy of the detection of incipient caries lesions in radiographs with PSP plates. Images with low spatial resolution seem to be more appropriate for this purpose.

15.
Oral Surg Oral Med Oral Pathol Oral Radiol ; 127(4): e102-e107, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30685389

RESUMO

OBJECTIVE: This study aimed to evaluate different materials as soft tissue simulators and the influence of soft tissues in cone beam computed tomography. STUDY DESIGN: Images of 5 piglet heads were acquired with intact soft tissues, with the tissues stripped, and with the use of different soft tissue simulators, following the same acquisition protocol. Four different materials were tested, individually or in combination: acrylic, water, utility wax, and expanded polystyrene (EPS). Pixel intensity values of 8 quadrangular regions, that is, upper and lower teeth and alveolar bone, were obtained. The mean values were used for comparison by analysis of variance (ANOVA; α = 5%). RESULTS: No differences were observed for the "No Material," "EPS," "Acrylic," and "EPS and Wax" groups for the lower anterior and posterior teeth, the upper posterior tooth, and the anterior and posterior bone, and for the "No Material," "EPS," and "EPS and Wax," groups for the lower posterior bone. All groups showed statistical differences for the lower anterior bone and the upper anterior tooth. CONCLUSIONS: Expanded 2-cm thick polystyrene, with or without 1-cm thick utility wax, was effective for most regions, followed by acrylic 0.5 cm. Soft tissues were not of great influence in most regions. Water was not an effective material for any of the regions.


Assuntos
Processo Alveolar , Tomografia Computadorizada de Feixe Cônico , Processo Alveolar/diagnóstico por imagem , Humanos
16.
Dentomaxillofac Radiol ; 48(2): 20180146, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30260235

RESUMO

OBJECTIVE:: To evaluate whether image enhancement filters of VistaScan system improve the diagnostic accuracy of simulated periapical lesions. METHODS:: 10 sockets were prepared on bovine ribs to fit a bovine tooth. Bone defects were created and successively enlarged providing four groups (n = 10): Group 0, absence of lesions; Group 1, periapical lesions with 1.6 mm in diameter; Group 2, with 1.8 mm in diameter; and Group 3, with 2.1 mm in diameter. Periapical radiographs were taken using a photostimulable storage phosphor plate and DBSWIN software. VistaScan filters were applied and the images were allocated into seven groups: Nonfiltered, Fine, Caries 1, Caries 2, Endodontic, Periodontal and Noise Reduction. All the 280 images were assessed about the presence or absence of periapical lesions. Pixel intensities standard deviation were compared between nonfiltered and filtered images. Two-Way Analysis of Variance and the post hoc Tukey's test were used to compare area under the ROC curve, sensitivity and specificity. RESULTS:: VistaScan filters showed no significant difference for area under receiver operating characteristic curve (p = 0.124), sensitivity (p = 0.835) and specificity (p = 0.832). Area under receiver operating characteristic curve (p = 0.000) and sensitivity (p = 0.000) in 2.1 mm lesions size were significantly higher than in 1.6 mm and 1.8 mm lesions size. Pixel intensities standard deviation was significantly changed in the filtered images compared to nonfiltered ones (p < 0.01), except for Fine in the bone region (p > 0.05). CONCLUSION:: VistaScan enhancement filters do not influence the diagnostic accuracy of simulated periapical lesions. On the other hand, larger lesions were more frequently detected. The filters change the pixel intensities reducing or intensifying the differences between similar regions.


Assuntos
Aumento da Imagem , Intensificação de Imagem Radiográfica , Radiografia Dentária Digital , Animais , Bovinos , Tomografia Computadorizada de Feixe Cônico , Curva ROC , Sensibilidade e Especificidade
17.
Dentomaxillofac Radiol ; 48(4): 20180340, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30563362

RESUMO

OBJECTIVE: To evaluate the influence of rotation degree and field of view (FOV) size on the amount of artefacts produced in cone beam CT (CBCT) images. METHODS: A cylindrical wax utility phantom, with a metallic sample in its interior, was scanned with two FOV sizes (100 x 100 and 40 x 40 mm) and in full (360°) and partial (~180°) rotations. After the acquisitions, images were objectively assessed in the ImageJ software, obtaining the standard deviation in areas around the metal sample. The influence of artefacts produced by the several FOVs and rotation degrees was compared by two-way analysis of variance (α = 0.05). RESULTS: The images obtained with a large FOV presented a higher amount of noise compared to a restricted FOV, both for partial (p = 0.0037) and full (p = 0.0023) rotation degrees. For images obtained with a restricted FOV, full rotation resulted in images with less noise (p = 0.0259). For images obtained with large FOV, there was no statistically significant difference (p = 0.1494) in noise for both rotation protocols. CONCLUSIONS: As there were no significant differences in the amount of artefacts in rotation protocols for large FOVs, the partial rotation can be indicated due to its lower exposure to radiation. For acquiring images with restricted FOVs, the full rotation is recommended.


Assuntos
Artefatos , Tomografia Computadorizada de Feixe Cônico , Imagens de Fantasmas , Rotação
18.
Imaging Sci Dent ; 48(1): 41-44, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29581948

RESUMO

PURPOSE: To evaluate the effect of different numbers of basis images and the use of metal artifact reduction (MAR) on the production and reduction of artifacts in cone-beam computed tomography images. MATERIALS AND METHODS: An acrylic resin phantom with a metal alloy sample was scanned, with 450 or 720 basis images and with or without MAR. Standard deviation values for the test areas (around the metal object) were obtained as a way of measuring artifact production. Two-way analysis of variance was used with a 5% significance level. RESULTS: There was no significant difference in artifact production among the images obtained with different numbers of basis images without MAR (P=.985). MAR significantly reduced artifact production in the test areas only in the protocol using 720 basis images (P=.017). The protocol using 450 basis images with MAR showed no significant difference in artifact production when compared to the protocol using 720 basis images with MAR (P=.579). CONCLUSION: Protocols with a smaller number of basis images and with MAR activated are preferable for minimizing artifact production in tomographic images without exposing the patient to a greater radiation dose.

19.
J Endod ; 44(4): 621-625, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29306535

RESUMO

INTRODUCTION: This study evaluated the image quality and the diagnosis of root fractures when using the Zoom Reconstruction tool (J Morita, Kyoto, Japan). METHODS: A utility wax phantom with a metal sample inside was used for objective evaluation, and a mandible with 27 single-rooted teeth (with and without obturation and with and without vertical or horizontal fractures) was used for diagnostic evaluation. The images were acquired in 3 protocols: protocol 1, field of view (FOV) of 4 × 4 cm and a voxel size of 0.08 mm; protocol 2, FOV of 10 × 10 cm and a voxel size of 0.2 mm; and protocol 3, Zoom Reconstruction of images from protocol 2 (FOV of 4 × 4 cm and a voxel size of 0.08 mm). The objective evaluation was achieved by measuring the image noise, and the diagnosis of fractures was performed by 3 evaluators. The area under the receiver operating characteristic curve was used to calculate accuracy, and analysis of variance compared the accuracy and image quality of the protocols. RESULTS: Regarding quality, protocol 1 was superior to protocol 2 (P < .0001) and Zoom Reconstruction (P < .0001). Additionally, images of protocol 2 presented less noise than the Zoom Reconstruction image (P < .0001); however, for diagnosis, Zoom Reconstruction was superior in relation to protocol 2 (P = .011) and did not differ from protocol 1 (P = .228) for the diagnosis of a vertical root fracture in filled teeth. CONCLUSIONS: The Zoom Reconstruction tool allows better accuracy for vertical root fracture detection in filled teeth, making it possible to obtain a higher-resolution image from a lower-resolution examination without having to expose the patient to more radiation.


Assuntos
Fraturas dos Dentes/diagnóstico por imagem , Raiz Dentária/lesões , Humanos , Processamento de Imagem Assistida por Computador/métodos , Técnicas In Vitro , Intensificação de Imagem Radiográfica/métodos , Radiografia Dentária/métodos , Reprodutibilidade dos Testes , Fraturas dos Dentes/diagnóstico , Raiz Dentária/diagnóstico por imagem
20.
Arch Oral Biol ; 87: 196-203, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29306777

RESUMO

OBJECTIVES: This systematic review was carried out to identify which naturally-occurring agents and constituents isolated therefrom have effects in preventing bone loss in a ligature-induced periodontitis model. MATERIALS AND METHODS: Eight databases were systematically searched for studies of experimental periodontitis. The data were extracted, analyzed, and the treatment outcomes were given scores based on the level of bone destruction as compared to their untreated induced-periodontitis control. RESULTS: 294 articles were found, of which 15 met the inclusion criteria. The selected studies tested a multi-herbal formulation; extracts (leaves, barks or fruit) of different plant species; and propolis. The most usual dosing protocol consisted of 3-times-a-day, 11-day treatment. The combined gel of Myracrodruon urundeuva (5%) and Lippia sidoides (0.5%) was the most active treatment, reducing 45-65% bone loss in the region of molars as compared to 73.4% of doxycycline (gold-standard). Ginkgo biloba extract (28-56 mg/kg) and propolis (100-200 mg/kg) prevented bone destruction by 50% and 40-44%, respectively. The other tested samples showed intermediate/weak activity in modulating bone resorption. CONCLUSIONS: The gel of M. urundeuva and L. sidoides, and G. biloba and propolis extracts showed strong alveolar bone protective effectiveness in induced-periodontitis in rats. Further translational research should bridge the gap between the rat study outcomes and the clinical efficacy and long-term toxicity of these formulations in humans. The compilation of the vast literature database presented herein may drive further in vivo and clinical studies with the selected efficacious formulations to subsidize their pharmaceutical application.


Assuntos
Perda do Osso Alveolar/prevenção & controle , Produtos Biológicos/farmacologia , Fitoterapia/métodos , Extratos Vegetais/farmacologia , Animais , Ginkgo biloba , Própole/farmacologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA